As a guideline for requesting
soil reports from GEO Technical firms use the following for your
particular tower.
Self
Support Towers
Provide one soil boring per
site and provide the following information at a minimum.
-
Allowable bearing pressure
at incremental depths to a depth of 20' for shallow foundation or 60'
plus or minus for drilled pier foundations
-
Water table below grade
-
Soil weight in pounds per
Cu. Ft.
-
Skin friction values if
drilled pier foundations are required
-
N values for all samples
-
Rock Quality Designation (RQD)
if rock foundations are required
-
Passive Pressure
coefficient for granular soils (KP), (PHI) and cohesion values for clay soils
(c)
GUYED
TOWERS
Provide four to seven soil
borings per site and provide the following information at a minimum.
-
Allowable bearing pressure required at
base (3' - 6' depth). All borings should be 15' to 20'
deep. If drilled pier foundations are anticipated, boring
depths should be increased to between 30' and 50'
-
Water table below grade
-
Soil weight in pounds per
Cu. Ft.
-
Skin friction values if
drilled pier foundations are required
-
N values for all samples
-
Rock Quality Designation (RQD)
if rock foundations are required
-
Passive Pressure
coefficient for granular soils (KP), (PHI) and cohesion values for clay soils
(c)
|